Profile
Staff
News
Locations
Contact Us
Home
Custom Manufactured Tanks
Selected Brass Tanks
Radiator Truck Parts
Return Policy
Policy Note
Warranty
Placing Orders
Electrical Wiring Inspection
AutoCar Bottom Tanks
AutoCar Misc.
AutoCar Side Frames
AutoCar Top Tanks
Bus Bottom Tanks
Bus Cross Flow Tanks
Bus Frames
Bus Misc.
Bus Top Tanks
Case Tanks and Frames
CAT
Champion Grader
Diamond Rio Bottom Tanks
Diamond Rio Side Frames
Diamond Rio Top Tank
Firetruck Tanks or Sets
Ford Bottom Tanks
Ford Cross Flow Tanks
Ford Frames
Ford Misc.
Ford Top Tanks
Freightliner Bottom Tanks
Freightliner Cross Flow Tanks
Freightliner Misc.
Freightliner Side Frames
Freightliner Surge Tanks
Freightliner Top Tanks
Generator Tanks or Sets
Gillig Bus
GMC Bottom Tanks
GMC Cross Flow Tanks
GMC Frames
GMC Top Tanks
Hovercraft
International Bottom Tanks
International Cross Flow Tanks
International Misc.
International Side Frames
International Top Tanks
John Deere Tanks or Sets
Kenworth Bottom Tanks
Kenworth Misc
Kenworth Side Frames
Kenworth Top Tanks
Komatsu Bolt-on Tanks
Locomotive
Mack Advance Bottom Tanks
Mack Advance Side Frames
Mack Advance Top Tanks
Mack Bottom Tanks
Mack Cross Flow Tanks
Mack Misc
Mack Side Frames
Mack Top Tanks
MCI Bus
Misc. Bolt on Tanks
Motor Home
New Flyer Bus
Nova Bus
Orion Bus
Oshkosh Bottom Tanks
Oshkosh Top Tanks
Ottawa Shunt Truck
PeterBilt Bottom Tanks
PeterBilt Misc.
PeterBilt Side Frames
PeterBilt Top Tanks
Thomas Bus Tanks and Frames
Western Star Bottom Tanks
Western Star Misc.
Western Star Side Frames
Western Star Top Tanks
Woodchipper Bolt-Ons
Bus Completes
CAT
Chevrolet
Core Type Configurations Available
Detroit Diesel
Dodge Ram
Ford
Freightliner
GM
International Cross Flow
ISUZU
Jeep
Kenworth
Lincoln
Mack Radiator
Navistar
Peterbilt
Toyota
TUG
Volvo
.Misc. Coolant Tubes
Freightliner Coolant Tubes
Kenworth Coolant Tubes
Peterbilt Coolant Tubes
Bus Solder-Ons
Caterpillar Solder-Ons
Cummins
Fire Truck Solder-ons
Ford Solder-Ons
Freightliner Solder Ons
Gen Set or Stationary Unit Solder-Ons
GMC Solder Ons
Hino Solder-Ons
Hitachi Solder-Ons
Hyster Lift Truck Solder-Ons
International Solder Ons
Isuzi Solder Ons
JCB Solder-ons
John Deere & Case Solder Ons
Komatsu Solder-ons
Kubota Solder-Ons
Lift Truck Solder-Ons (misc.)
Lincoln Welder
Mack Solder Ons
Misc. Solder On Tanks
Mitsubishi Solder-Ons
Motor Home Solder Ons
New Holland Solder-ons
Nissan Solder ons
PeterBilt/Kenworth Solder Ons
Toyota Solder Ons
Volvo/GMC Solder Ons
Western Star Solder ons
Woodchipper Solder-Ons
Accessories
Boil Out Tanks
Flush Spray Booths
Hoists / Lifts
SandBlasters
Teardown Station
Test Tank C/W Lift
Test Tanks
Antique Restorations
Chemical Shop Supplies
Filler Necks
Gasket Tape
Gloves
Header Clamps
Heater Block
Hydraulic Tanks / Utility Tanks
Oil Coolers
Sightglasses and Flanges
Stackable Bins
Tables and Benches
Tester Kits
Products
Search Our Parts Catalogue
5 results found!
Taalman #50 Boil Out Tank
This mini boil out tank -ideal for the radiator shop that is tight for space or as a "add on" to your existing Industrial shop. It has all the requirements of a bigger tank Without losing valuable space! Advantages include : Inner shell construction from heavy steel; 2" thick insulation on sides, front, back and lid. Enclosed with steel plates to minimize heat loss; Reinforced lid to prevent twisting; Removable grade for easy cleaning; Lid can be opened manually or with optional air cylinder; Safety bar for your added safety; Air agitator in back; Available in electric heating only--Model 50 (mini) ; Ship weight 700 lbs; Overall dim 44"X34"X35"; Heating 1 -3KW element; Voltage, single phase~2301600 volts;Maxamperageaf230v l3amp; Max amperage a' 600V 6 amp;Air cylinder 1 – 2” diameter (optional) ;Lifting capacity manual;Liquid capacity 155 gal; Dipping space 40'x30"30";Thermostat 1 0 -120 degree Celsius
Electrical Device Wiring Inspection
Taalman electric boil-out tanks contain electric heating elements, and electrically controlled thermostat and power switches. Gas boil-out tanks are gas fired, but also have electrically controlled thermostat and power switches.
These items require CSA / ESA or equivalent approval, and must be wired up by a licensed electrician. Approval may be obtained for an at-cost fee by Taalman, or the purchaser can opt to have approval done at their own place of operation, at their own cost.
Taalman #140 Hot Tank
BOIL OUT TANKS -TOUGH AND LASTING--Advantages: 3 standard sizes available, all built with the same features. Just order small, medium or large. All 3 are available with electric or gas heating; Innershell construction from extra heavy duty steel plates for lasting value; Reinforced lid to prevent twisting; Removable grade for easy cleaning; Smooth easy lid and grade lifting by air cylinders mounted on each side of tank and operated by control valve; Air agitator in rear of tank; Maximum lid opening for easy loading and unloading of radiators; Safety bars for your added protection Specifications: Shipping weight 2200 lbs; Overall dim. 61x102x37; Heating Elements 2 - 4KW; Voltage, single phase~230/600V*; Max.amp at 230V 36.4 amp; Max. amp at 600V 14 amp; Air cylinders 2- 4" dla; Lifting cap. e 100 PSI 2500 lbs; Liquid capacity 550 gall; Dipping space w / lift 5~x80x21; Dipping space w /out lift 59x86x27; Thermostat 11 0-120C; Contactor at 230V 1 - 40 amp; Contactor at 600V 1-20 amp
Electrical Device Wiring Inspection
Taalman electric boil-out tanks contain electric heating elements, and electrically controlled thermostat and power switches. Gas boil-out tanks are gas fired, but also have electrically controlled thermostat and power switches.
These items require CSA / ESA or equivalent approval, and must be wired up by a licensed electrician. Approval may be obtained for an at-cost fee by Taalman, or the purchaser can opt to have approval done at their own place of operation, at their own cost.
Taalman #120 Hot Tank
BOIL OUT TANKS -TOUGH AND LASTING--Advantages: 3 standard sizes available, all built with the same features. Just order small, medium or large. All 3 are available with electric or gas heating; Innershell construction from extra heavy duty steel plates for lasting value; Reinforced lid to prevent twisting; Removable grade for easy cleaning; Smooth easy lid and grade lifting by air cylinders mounted on each side of tank and operated by control valve; Air agitator in rear of tank; Maximum lid opening for easy loading and unloading of radiators; Safety bars for your added protection Specifications: Shipping weight 1670 lbs; Overall dim. 62x79x34; Heating Elements 2-3KW; Voltage, single phase~230/600V*; Max.amp at 230V 27.5 amp; Max. amp at 600V 10.5 amp; Air cylinders 2 - 3" dia; Lifting cap. e 100 PSI 1200 lbs; Liquid capacity 350 gal; Dipping space w / lift 53x60x18; Dipping space w /out lift 53x65x24; Thermostat 1 0-120C; Contactor at 230V 1-30 amp; Contactor at 600V 1 - 20 amp
Electrical Device Wiring Inspection
Taalman electric boil-out tanks contain electric heating elements, and electrically controlled thermostat and power switches. Gas boil-out tanks are gas fired, but also have electrically controlled thermostat and power switches.
These items require CSA / ESA or equivalent approval, and must be wired up by a licensed electrician. Approval may be obtained for an at-cost fee by Taalman, or the purchaser can opt to have approval done at their own place of operation, at their own cost.
Taalman #100 Hot Tank
BOIL OUT TANKS -TOUGH AND LASTING--Advantages: 3 standard sizes available, all built with the same features. Just order small, medium or large. All 3 are available with electric or gas heating; Innershell construction from extra heavy duty steel plates for lasting value; Reinforced lid to prevent twisting; Removable grade for easy cleaning; Smooth easy lid and grade lifting by air cylinders mounted on each side of tank and operated by control valve; Air agitator in rear of tank; Maximum lid opening for easy loading and unloading of radiators; Safety bars for your added protection Specifications: Shipping weight 1200 lbs; Overall dim. 50x66x34; Heating Elements 1 - 4KW; Voltage, single phase~230/600V*; Max.amp at 230V 18.2 amp; Max. amp at 600V 1 amp; Air cylinders 2 - 2" dia; Lifting cap. e 100 PSI 500 lbs; Liquid capacity 180 gal; Dipping space w / lift 41x49x18; Dipping space w /out lift 41x53x24; Thermostat 1 0-120C; Contactor at 230V None; Contactor at 600V None
Electrical Device Wiring Inspection
Taalman electric boil-out tanks contain electric heating elements, and electrically controlled thermostat and power switches. Gas boil-out tanks are gas fired, but also have electrically controlled thermostat and power switches.
These items require CSA / ESA or equivalent approval, and must be wired up by a licensed electrician. Approval may be obtained for an at-cost fee by Taalman, or the purchaser can opt to have approval done at their own place of operation, at their own cost.
#021910A - Boil Out Tank
Custom order Boil Out Tank
This boil out tank has dimensions of 91" x 30" x 30". It was designed specifically for use with Cat modular cores and Cat folded cores.
Electrical Device Wiring Inspection
Taalman electric boil-out tanks contain electric heating elements, and electrically controlled thermostat and power switches. Gas boil-out tanks are gas fired, but also have electrically controlled thermostat and power switches.
These items require CSA / ESA or equivalent approval, and must be wired up by a licensed electrician. Approval may be obtained for an at-cost fee by Taalman, or the purchaser can opt to have approval done at their own place of operation, at their own cost.
Taalman, Inc. ©2008 All Rights Reserved.
Privacy Policy